Results for: Costa Rica
Filters
CMC Quick search Filters close;
?
Added keywords act as an additional filter. Keywords separated by a space will be treated by the logical function AND automatically. You may also use OR. Keyword searches also find close matches. Placing quotation marks (") before and after the search word, e.g. "word", will allow for exact matches.

In case of multiple search, please use ADVANCED SEARCH.
94 results
Reset all
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a 2 + b 2]1/2
Unless otherwise stated the expanded uncertainties given below correspond to k = 2 (at a 95 % level of confidence)
Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas)
AC voltage (up to the MHz range) , AC voltage (up to the MHz range): AC voltage up to 1100 V, meters : 0.01 V to 1000 V
AC voltmeter, multimeter, multifunction calibrator
Relative expanded uncertainty : 5.0E1 µV/V to 1.1E4 µV/V
{"row_1":{"col_1":"","col_2":"10 Hz","col_3":"45 Hz","col_4":"60 Hz","col_5":"1 kHz","col_6":"10 kHz","col_7":"20 kHz","col_8":"50 kHz","col_9":"100 kHz","col_10":"300 kHz","col_11":"500 kHz","col_12":"1 MHz"},"row_2":{"col_1":"10 mV","col_2":"640","col_3":"480","col_4":"480","col_5":"480","col_6":"480","col_7":"480","col_8":"600","col_9":"1000","col_10":"2050","col_11":"3400","col_12":"4700"},"row_3":{"col_1":"30 mV","col_2":"640","col_3":"313","col_4":"313","col_5":"313","col_6":"313","col_7":"313","col_8":"433","col_9":"1027","col_10":"1567","col_11":"2233","col_12":"4200"},"row_4":{"col_1":"100 mV","col_2":"360","col_3":"150","col_4":"150","col_5":"150","col_6":"150","col_7":"150","col_8":"270","col_9":"630","col_10":"1100","col_11":"1650","col_12":"3150"},"row_5":{"col_1":"300 mV","col_2":"373","col_3":"72","col_4":"72","col_5":"72","col_6":"72","col_7":"72","col_8":"108","col_9":"210","col_10":"687","col_11":"1667","col_12":"2700"},"row_6":{"col_1":"1 V","col_2":"280","col_3":"53","col_4":"53","col_5":"53","col_6":"53","col_7":"53","col_8":"85","col_9":"140","col_10":"500","col_11":"1200","col_12":"2000"},"row_7":{"col_1":"3 V","col_2":"373","col_3":"62","col_4":"62","col_5":"62","col_6":"62","col_7":"62","col_8":"108","col_9":"167","col_10":"475","col_11":"1667","col_12":"2567"},"row_8":{"col_1":"10 V","col_2":"280","col_3":"50","col_4":"50","col_5":"50","col_6":"50","col_7":"50","col_8":"85","col_9":"120","col_10":"335","col_11":"1200","col_12":"1820"},"row_9":{"col_1":"30 V","col_2":"373","col_3":"72","col_4":"72","col_5":"72","col_6":"72","col_7":"72","col_8":"113","col_9":"233","col_10":"1433","col_11":"5733","col_12":"10667"},"row_10":{"col_1":"100 V","col_2":"280","col_3":"58","col_4":"58","col_5":"58","col_6":"58","col_7":"58","col_8":"90","col_9":"175","col_10":"1060","col_11":"4800","col_12":"8800"},"row_11":{"col_1":"300 V","col_2":"–","col_3":"103","col_4":"103","col_5":"103","col_6":"185","col_7":"185","col_8":"–","col_9":"–","col_10":"–","col_11":"–","col_12":"–"},"row_12":{"col_1":"900 V","col_2":"–","col_3":"94","col_4":"94","col_5":"94","col_6":"172","col_7":"172","col_8":"–","col_9":"–","col_10":"–","col_11":"–","col_12":"–"}}
The expanded uncertainties given in this table are expressed in µV/V
Direct comparison
Frequency : 10 Hz to 1 MHz
Approved on 23 March 2010
Institute service identifier : ICE-LMVE/52201
CMC ID : SIM-EM-CR-000007QL-1
 
DC current (up to 100 A) , DC current sources: low values : 1.00E-5 A to 1.00E-4 A
Multifunction calibrator, current generator
Relative expanded uncertainty : 1.0E2 µA/A to 8.0E2 µA/A
{"row_1":{"col_1":"Current Value","col_2":"Expanded Uncertainty","col_3":"Units"},"row_2":{"col_1":"0.01 mA","col_2":"800","col_3":"µA/A<br>"},"row_3":{"col_1":"&gt; 0.01 mA","col_2":"175","col_3":"µA/A<strong>​​​​​​​</strong><br>"},"row_4":{"col_1":"0.1 mA","col_2":"100","col_3":"µA/A<br>"}}
Direct comparison
Approved on 21 December 2023
Institute service identifier : ICE-LMVE/31101
CMC ID : SIM-EM-CR-00000NUK-1
 
DC current (up to 100 A) , DC current meters: intermediate values : 1.01E-4 A to 10 A
Multimeter
Relative expanded uncertainty : 1.0E1 µA/A to 1.0E3 µA/A
{"row_1":{"col_1":"Current Value","col_2":"Expanded Uncertainty","col_3":"Value"},"row_2":{"col_1":"&gt; 1 mA","col_2":"60","col_3":"µA/A"},"row_3":{"col_1":"&gt; 2.2 mA","col_2":"120","col_3":"µA/A"},"row_4":{"col_1":"10 mA","col_2":"10","col_3":"µA/A"},"row_5":{"col_1":"&gt; 10 mA","col_2":"60","col_3":"µA/A<br>"},"row_6":{"col_1":"&gt; 22 mA","col_2":"150","col_3":"µA/A"},"row_7":{"col_1":"100 mA","col_2":"15","col_3":"µA/A"},"row_8":{"col_1":"&gt; 100 mA","col_2":"70","col_3":"µA/A"},"row_9":{"col_1":"&gt; 220 mA","col_2":"235","col_3":"µA/A"},"row_10":{"col_1":"1 A","col_2":"10","col_3":"µA/A"},"row_11":{"col_1":"&gt; 1 A","col_2":"125","col_3":"µA/A"},"row_12":{"col_1":"&gt; 2 A","col_2":"1000","col_3":"µA/A"},"row_13":{"col_1":"10 A","col_2":"45","col_3":"µA/A"}}
Comparison with reference standard, direct comparison
Approved on 21 December 2023
Institute service identifier : ICE-LMVE/32202
CMC ID : SIM-EM-CR-00000NUO-1
 
AC power , AC power and energy: single phase (frequency <= 400 Hz) : 0.39 W to 57.6 W
Watt-hour meter, wattmeter
Relative expanded uncertainty : 6.5E1 µW (VA)-1 to 1.1E2 µW (VA)-1
{"row_1":{"col_1":"Current (A)","col_2":"Degrees (°)","col_3":"51.96 V","col_4":"57.74 V","col_5":"60 V","col_6":"63.15 V","col_7":"108 V","col_8":"120 V","col_9":"132 V","col_10":"240 V","col_11":"277 V","col_12":"480 V"},"row_2":{"col_1":"0.015, 0.025, 0.05","col_2":"0","col_3":"<br>","col_4":"70","col_5":"<br>","col_6":"<br>","col_7":"<br>","col_8":"<br>","col_9":"","col_10":"","col_11":"","col_12":""},"row_3":{"col_1":"0.025","col_2":"0","col_3":"70","col_4":"<br>","col_5":"<br>","col_6":"70","col_7":"<br>","col_8":"<br>","col_9":"<br>","col_10":"","col_11":"","col_12":""},"row_4":{"col_1":"0.1","col_2":"-60","col_3":"<br>","col_4":"70","col_5":"","col_6":"","col_7":"","col_8":"","col_9":"","col_10":"","col_11":"","col_12":""},"row_5":{"col_1":"0.15, 0.25, 0.5, 1.2, 1.5, 1.8, 2.0, 2.5, 5.0, 7.5, 10","col_2":"0","col_3":"<br>","col_4":"65","col_5":"","col_6":"","col_7":"","col_8":"","col_9":"","col_10":"","col_11":"","col_12":"<br>"},"row_6":{"col_1":"0.25, 2.5","col_2":"0","col_3":"65","col_4":"","col_5":"","col_6":"","col_7":"","col_8":"","col_9":"","col_10":"","col_11":"<br>","col_12":"<br>"},"row_7":{"col_1":"1.0, 2.0, 2.5, 5.0, 10.0","col_2":"-60","col_3":"<br>","col_4":"65","col_5":"<br>","col_6":"","col_7":"<br>","col_8":"<br>","col_9":"","col_10":"<br>","col_11":"<br>","col_12":""},"row_8":{"col_1":"0,5","col_2":"-60","col_3":"<br>","col_4":"75","col_5":"","col_6":"","col_7":"","col_8":"","col_9":"","col_10":"","col_11":"","col_12":""},"row_9":{"col_1":"1","col_2":"0","col_3":"<br>","col_4":"75","col_5":"","col_6":"","col_7":"","col_8":"","col_9":"","col_10":"","col_11":"","col_12":""},"row_10":{"col_1":"2.5","col_2":"0","col_3":"<br>","col_4":"<br>","col_5":"65","col_6":"<br>","col_7":"","col_8":"","col_9":"","col_10":"","col_11":"","col_12":""},"row_11":{"col_1":"0.25, 2.5","col_2":"0","col_3":"<br>","col_4":"<br>","col_5":"<br>","col_6":"65","col_7":"","col_8":"<br>","col_9":"","col_10":"","col_11":"","col_12":""},"row_12":{"col_1":"0.15, 0.25, 0.5, 1.5, 2.5, 5.0, 10.0","col_2":"0","col_3":"<br>","col_4":"<br>","col_5":"<br>","col_6":"<br>","col_7":"<br>","col_8":"65","col_9":"<br>","col_10":"","col_11":"","col_12":""},"row_13":{"col_1":"1.0, 2.5, 3.0, 5.0, 10.0","col_2":"60","col_3":"<br>","col_4":"<br>","col_5":"<br>","col_6":"","col_7":"","col_8":"65","col_9":"<br>","col_10":"<br>","col_11":"","col_12":"<br>"},"row_14":{"col_1":"0.5, 1.0, 2.5, 3.0, 5.0, 10.0","col_2":"-60","col_3":"","col_4":"<br>","col_5":"<br>","col_6":"","col_7":"","col_8":"65","col_9":"<br>","col_10":"","col_11":"","col_12":"<br>"},"row_15":{"col_1":"0.15, 0.2, 0.5, 1.0, 2.5, 3.0, 5.0, 6.0, 7.5, 10.0","col_2":"0","col_3":"<br>","col_4":"<br>","col_5":"<br>","col_6":"<br>","col_7":"<br>","col_8":"<br>","col_9":"<br>","col_10":"65","col_11":"","col_12":""},"row_16":{"col_1":"1.0, 2.5, 5.0","col_2":"60","col_3":"<br>","col_4":"<br>","col_5":"","col_6":"","col_7":"","col_8":"","col_9":"<br>","col_10":"65","col_11":"","col_12":""},"row_17":{"col_1":"1.0, 2.5, 5.0","col_2":"-60","col_3":"","col_4":"","col_5":"<br>","col_6":"<br>","col_7":"<br>","col_8":"<br>","col_9":"<br>","col_10":"65","col_11":"<br>","col_12":""},"row_18":{"col_1":"0.2, 5.0, 10, 30, 50, 100, 120","col_2":"0","col_3":"<br>","col_4":"<br>","col_5":"<br>","col_6":"<br>","col_7":"<br>","col_8":"<br>","col_9":"<br>","col_10":"<br>","col_11":"<br>","col_12":"110"},"row_19":{"col_1":"5, 50","col_2":"60","col_3":"<br>","col_4":"<br>","col_5":"<br>","col_6":"<br>","col_7":"","col_8":"","col_9":"","col_10":"","col_11":"<br>","col_12":"110"},"row_20":{"col_1":"0.2, 5, 10, 30, 50, 100","col_2":"-60","col_3":"<br>","col_4":"","col_5":"<br>","col_6":"<br>","col_7":"<br>","col_8":"<br>","col_9":"<br>","col_10":"<br>","col_11":"<br>","col_12":"110"},"row_21":{"col_1":"15, 18, 20","col_2":"0","col_3":"<br>","col_4":"80","col_5":"","col_6":"","col_7":"<br>","col_8":"","col_9":"","col_10":"","col_11":"","col_12":"<br>"},"row_22":{"col_1":"20","col_2":"-60","col_3":"<br>","col_4":"80","col_5":"","col_6":"","col_7":"<br>","col_8":"","col_9":"<br>","col_10":"<br>","col_11":"<br>","col_12":"<br>"},"row_23":{"col_1":"30","col_2":"0","col_3":"<br>","col_4":"<br>","col_5":"<br>","col_6":"<br>","col_7":"80","col_8":"<br>","col_9":"80","col_10":"<br>","col_11":"110","col_12":"<br>"},"row_24":{"col_1":"12, 15, 18, 20, 30, 50, 60","col_2":"0","col_3":"<br>","col_4":"<br>","col_5":"<br>","col_6":"<br>","col_7":"<br>","col_8":"80","col_9":"","col_10":"","col_11":"","col_12":""},"row_25":{"col_1":"30, 50","col_2":"60","col_3":"<br>","col_4":"<br>","col_5":"<br>","col_6":"<br>","col_7":"<br>","col_8":"80","col_9":"","col_10":"","col_11":"","col_12":""},"row_26":{"col_1":"20, 30, 50","col_2":"-0","col_3":"<br>","col_4":"","col_5":"","col_6":"","col_7":"","col_8":"80","col_9":"","col_10":"","col_11":"","col_12":""},"row_27":{"col_1":"15, 20, 30, 50, 60","col_2":"0","col_3":"<br>","col_4":"<br>","col_5":"<br>","col_6":"<br>","col_7":"<br>","col_8":"<br>","col_9":"80","col_10":"<br>","col_11":"","col_12":""},"row_28":{"col_1":"30, 50","col_2":"60","col_3":"","col_4":"","col_5":"","col_6":"","col_7":"","col_8":"","col_9":"80","col_10":"","col_11":"<br>","col_12":"<br>"},"row_29":{"col_1":"30, 50","col_2":"-60","col_3":"","col_4":"","col_5":"<br>","col_6":"","col_7":"","col_8":"<br>","col_9":"80","col_10":"<br>","col_11":"","col_12":""},"row_30":{"col_1":"30","col_2":"60, -60","col_3":"","col_4":"","col_5":"<br>","col_6":"<br>","col_7":"","col_8":"","col_9":"<br>","col_10":"110","col_11":"","col_12":""},"row_31":{"col_1":"75, 90, 100, 120","col_2":"0","col_3":"","col_4":"","col_5":"","col_6":"<br>","col_7":"110","col_8":"<br>","col_9":"110","col_10":"<br>","col_11":"","col_12":"<br>"},"row_32":{"col_1":"100","col_2":"60, -60","col_3":"<br>","col_4":"<br>","col_5":"","col_6":"","col_7":"110","col_8":"","col_9":"","col_10":"<br>","col_11":"<br>","col_12":"<br>"}}
All values at 60 Hz
Comparison
Frequency : 60 Hz
Applied Voltage : 51.96 V to 480 V
Current : 0.015 A to 120 A
Power factor  : 1, 0.5 lead, 0.5 lag
Approved on 06 March 2024
Institute service identifier : ICE-LMVE/71101
CMC ID : SIM-EM-CR-00000NV2-1
 
AC current , AC current up to 100 A: meters : 1.00E-4 A to 11 A
AC ammeter, multimeter, multifunction calibrator
Relative expanded uncertainty : 1.1E2 µA/A to 5.8E3 µA/A
{"row_1":{"col_1":"","col_2":"10 Hz","col_3":"45 Hz","col_4":"60 Hz","col_5":"1 kHz","col_6":"5 kHz","col_7":"10 kHz"},"row_2":{"col_1":"220 µA","col_2":"318","col_3":"155","col_4":"155","col_5":"155","col_6":"–","col_7":"1359"},"row_3":{"col_1":"2.2 mA","col_2":"298","col_3":"184","col_4":"184","col_5":"184","col_6":"–","col_7":"2536"},"row_4":{"col_1":"2.2 mA","col_2":"225","col_3":"120","col_4":"120","col_5":"120","col_6":"–","col_7":"1359"},"row_5":{"col_1":"22 mA","col_2":"298","col_3":"184","col_4":"184","col_5":"184","col_6":"–","col_7":"2148"},"row_6":{"col_1":"22 mA","col_2":"225","col_3":"120","col_4":"120","col_5":"120","col_6":"198","col_7":"1242"},"row_7":{"col_1":"220 mA","col_2":"298","col_3":"158","col_4":"158","col_5":"158","col_6":"–","col_7":"1113"},"row_8":{"col_1":"220 mA","col_2":"225","col_3":"113","col_4":"113","col_5":"113","col_6":"–","col_7":"932"},"row_9":{"col_1":"2.2 A","col_2":"–","col_3":"292","col_4":"292","col_5":"292","col_6":"–","col_7":"5849"},"row_10":{"col_1":"2.2 A","col_2":"–","col_3":"229","col_4":"229","col_5":"229","col_6":"411","col_7":"5559"},"row_11":{"col_1":"11 A","col_2":"–","col_3":"401","col_4":"401","col_5":"401","col_6":"–","col_7":"2989"},"row_12":{"col_1":"11 A","col_2":"–","col_3":"370","col_4":"370","col_5":"370","col_6":"–","col_7":"2853"}}
The expanded uncertainties given in this table are expressed in µA/A (uncertainty values depend on range and output)
Direct comparison
Frequency : 10 Hz to 10 kHz
Approved on 23 March 2010
Institute service identifier : ICE-LMVE/62201
CMC ID : SIM-EM-CR-000007QN-1
 
DC current (up to 100 A) , DC current meters: low values : 1.00E-5 A to 11 A
Multimeter
Relative expanded uncertainty : 4.0E1 µA/A to 8.4E2 µA/A
{"row_1":{"col_1":"","col_2":"Expanded Uncertainty","col_3":"Units"},"row_2":{"col_1":"0.01 mA","col_2":"656","col_3":"µA/A"},"row_3":{"col_1":"0.1 mA","col_2":"102","col_3":"µA/A"},"row_4":{"col_1":"&gt; 0.1 mA","col_2":"107","col_3":"µA/A"},"row_5":{"col_1":"1 mA","col_2":"43","col_3":"µA/A"},"row_6":{"col_1":"&gt; 1 mA","col_2":"77","col_3":"µA/A"},"row_7":{"col_1":"10 mA","col_2":"40","col_3":"µA/A"},"row_8":{"col_1":"&gt; 10 mA","col_2":"117","col_3":"µA/A"},"row_9":{"col_1":"100 mA","col_2":"53","col_3":"µA/A"},"row_10":{"col_1":"&gt; 100 mA","col_2":"204","col_3":"µA/A"},"row_11":{"col_1":"1 A","col_2":"94","col_3":"µA/A"},"row_12":{"col_1":"&gt;1 A","col_2":"840","col_3":"µA/A"},"row_13":{"col_1":"11 A","col_2":"404","col_3":"µA/A"}}
Direct comparison
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/32101
CMC ID : SIM-EM-CR-000007QX-1
 
DC voltage (up to 1100 V) , DC voltage sources: low value ranges : 0.01 V to 10 V
DC voltage source, multifunction calibrator
Relative expanded uncertainty : 5 µV/V to 2.8E2 µV/V
{"row_1":{"col_1":"Voltage Value","col_2":"Expanded Uncertainty","col_3":"Units"},"row_2":{"col_1":"10 mV<br>","col_2":"75","col_3":"µV/V"},"row_3":{"col_1":"&gt; 10 mV<br>","col_2":"280","col_3":"µV/V"},"row_4":{"col_1":"100 mV<br>","col_2":"10","col_3":"µV/V"},"row_5":{"col_1":"&gt; 100 mV","col_2":"10","col_3":"µV/V<br>"},"row_6":{"col_1":"1 V<br>","col_2":"5","col_3":"µV/V"},"row_7":{"col_1":"&gt;&nbsp;1 V","col_2":"10","col_3":"µV/V<br>"},"row_8":{"col_1":"10 V","col_2":"5","col_3":"µV/V<br>"}}
Direct comparison
Approved on 21 December 2023
Institute service identifier : ICE-LMVE/11201
CMC ID : SIM-EM-CR-00000NUD-1
 
Impedance (up to the MHz range) , Inductance: self inductance, low values : 10 mH to 100 mH
Fixed inductor
Relative expanded uncertainty : 5.0E1 µH/H
{"row_1":{"col_1":"","col_2":"Parameter","col_3":"Specifications","col_4":"Expanded uncertainty","col_5":"Units"},"row_2":{"col_1":"10 mH","col_2":"Frequency Current","col_3":"1 kHz 7.7 mA","col_4":"50","col_5":"µH/H"},"row_3":{"col_1":"100 mH","col_2":"Frequency Current","col_3":"1 kHz 1.5 mA","col_4":"50","col_5":"µH/H"}}
Substitution using an LCR meter
Frequency : 1 kHz
Current : 1.5 mA to 7.7 mA
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/43201
CMC ID : SIM-EM-CR-000007QJ-1
 
AC power , AC power and energy: single phase (frequency <= 400 Hz) : 15 W to 1.20E4 W
Watt-hour meter, wattmeter
Relative expanded uncertainty : 2.9E2 µW (VA)-1
Comparison
Frequency : 60 Hz
Applied voltage : 120 V and 240 V
Current : (0.25 A at 120 V and 0.3 A at 240 V) to 50 A
Power factor : 1, 0.5 lead, 0.5 lag
Approved on 23 March 2010
Institute service identifier : ICE-LMVE/71101
CMC ID : SIM-EM-CR-000007QO-1
 
DC voltage (up to 1100 V) , DC voltage meters: intermediate values : 1.00E-3 V to 0.01 V
DC voltmeter, multimeter
Relative expanded uncertainty : 3.8 µV/V to 4.2E2 µV/V
{"row_1":{"col_1":"","col_2":"Expanded uncertainty","col_3":"Units"},"row_2":{"col_1":"&gt; 0.001 V DC","col_2":"416","col_3":"µV/V"},"row_3":{"col_1":"0.01 V DC","col_2":"48","col_3":"µV/V"},"row_4":{"col_1":"&gt; 0.01 V DC","col_2":"48","col_3":"µV/V"},"row_5":{"col_1":"0.1 V DC","col_2":"12","col_3":"µV/V"},"row_6":{"col_1":"&gt; 0.1 V DC","col_2":"12","col_3":"µV/V"},"row_7":{"col_1":"1 V DC","col_2":"5.8","col_3":"µV/V"},"row_8":{"col_1":"&gt; 1 V DC","col_2":"5.8","col_3":"µV/V"},"row_9":{"col_1":"10 V DC","col_2":"3.8","col_3":"µV/V"},"row_10":{"col_1":"&gt; 10 V DC","col_2":"3.8","col_3":"µV/V"},"row_11":{"col_1":"100 V DC","col_2":"5.5","col_3":"µV/V"},"row_12":{"col_1":"&gt;100 V DC","col_2":"5.5","col_3":"µV/V"},"row_13":{"col_1":"1000 V DC","col_2":"7","col_3":"µV/V"}}
Direct comparison
Measurement lower limit for values > 0.001 V
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/12201
CMC ID : SIM-EM-CR-000007QQ-1
 
DC resistance , DC resistance standards and sources: low values : 0.1 Ω to 1.00E8 Ω
Fixed resistor, resistance box
Relative expanded uncertainty : 1.0E1 µΩ/Ω to 4.7E2 µΩ/Ω
{"row_1":{"col_1":"","col_2":"Expanded uncertainty","col_3":"Units"},"row_2":{"col_1":"0.1 Ω","col_2":"402","col_3":"µΩ/Ω"},"row_3":{"col_1":"1 Ω","col_2":"53","col_3":"µΩ/Ω"},"row_4":{"col_1":"&gt; 1 Ω","col_2":"53","col_3":"µΩ/Ω"},"row_5":{"col_1":"10 Ω","col_2":"18","col_3":"µΩ/Ω"},"row_6":{"col_1":"&gt; 10 Ω","col_2":"50","col_3":"µΩ/Ω"},"row_7":{"col_1":"100 Ω","col_2":"16","col_3":"µΩ/Ω"},"row_8":{"col_1":"&gt; 100 Ω","col_2":"14","col_3":"µΩ/Ω"},"row_9":{"col_1":"1 kΩ","col_2":"10","col_3":"µΩ/Ω"},"row_10":{"col_1":"&gt; 1 kΩ","col_2":"14","col_3":"µΩ/Ω"},"row_11":{"col_1":"10 kΩ","col_2":"10","col_3":"µΩ/Ω"},"row_12":{"col_1":"&gt; 10 kΩ","col_2":"14","col_3":"µΩ/Ω"},"row_13":{"col_1":"100 kΩ","col_2":"10","col_3":"µΩ/Ω"},"row_14":{"col_1":"&gt; 100 kΩ","col_2":"30","col_3":"µΩ/Ω"},"row_15":{"col_1":"1 MΩ","col_2":"16","col_3":"µΩ/Ω"},"row_16":{"col_1":"&gt; 1 MΩ","col_2":"119","col_3":"µΩ/Ω"},"row_17":{"col_1":"10 MΩ","col_2":"49","col_3":"µΩ/Ω"},"row_18":{"col_1":"&gt; 10 MΩ","col_2":"468","col_3":"µΩ/Ω"},"row_19":{"col_1":"100 MΩ","col_2":"398","col_3":"µΩ/Ω"}}
Direct comparison
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/21101
CMC ID : SIM-EM-CR-000007QR-1
 
DC current (up to 100 A) , DC current sources: low values : 1.00E-5 A to 10 A
Multifunction calibrator, current generator
Relative expanded uncertainty : 2.3E1 µA/A to 4.2E2 µA/A
{"row_1":{"col_1":"","col_2":"Expanded Uncertainty","col_3":"Units"},"row_2":{"col_1":"0.01 mA","col_2":"82","col_3":"µA/A"},"row_3":{"col_1":"0.1 mA","col_2":"26","col_3":"µA/A"},"row_4":{"col_1":"&gt; 0.1 mA","col_2":"59","col_3":"µA/A"},"row_5":{"col_1":"1 mA","col_2":"23","col_3":"µA/A"},"row_6":{"col_1":"&gt; 1 mA","col_2":"59","col_3":"µA/A"},"row_7":{"col_1":"10 mA","col_2":"23","col_3":"µA/A"},"row_8":{"col_1":"&gt; 10 mA","col_2":"70","col_3":"µA/A"},"row_9":{"col_1":"100 mA","col_2":"35","col_3":"µA/A"},"row_10":{"col_1":"&gt; 100 mA","col_2":"167","col_3":"µA/A"},"row_11":{"col_1":"1 A","col_2":"97","col_3":"µA/A"},"row_12":{"col_1":"&gt;1 A","col_2":"235","col_3":"µA/A"},"row_13":{"col_1":"10 A","col_2":"418","col_3":"µA/A"}}
Direct comparison
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/31101
CMC ID : SIM-EM-CR-000007QW-1
 
DC voltage (up to 1100 V) , DC voltage sources: low value ranges : 0.01 V to 1000 V
DC voltage source, multifunction calibrator
Relative expanded uncertainty : 4.9 µV/V to 1.6E2 µV/V
{"row_1":{"col_1":"","col_2":"Expanded uncertainty","col_3":"Units"},"row_2":{"col_1":"0.01 V DC","col_2":"161","col_3":"µV/V"},"row_3":{"col_1":"0.1 V DC","col_2":"21","col_3":"µV/V"},"row_4":{"col_1":"&gt; 0.1 V DC","col_2":"21","col_3":"µV/V"},"row_5":{"col_1":"1 V DC","col_2":"6.2","col_3":"µV/V"},"row_6":{"col_1":"&gt; 1 V DC","col_2":"6.2","col_3":"µV/V"},"row_7":{"col_1":"10 V DC","col_2":"4.9","col_3":"µV/V"},"row_8":{"col_1":"&gt; 10 V DC","col_2":"4.9","col_3":"µV/V"},"row_9":{"col_1":"100 V DC","col_2":"6.4","col_3":"µV/V"},"row_10":{"col_1":"&gt;100 V DC","col_2":"6.4","col_3":"µV/V"},"row_11":{"col_1":"1000 V DC","col_2":"15.6","col_3":"µV/V"}}
Direct comparison
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/11201
CMC ID : SIM-EM-CR-000007QP-1
 
DC current (up to 100 A) , DC current meters: low values : 1.00E-5 A to 1.00E-4 A
Multimeter
Relative expanded uncertainty : 2.0E1 µA/A to 1.1E3 µA/A
{"row_1":{"col_1":"Current Value","col_2":"Expanded Uncertainty","col_3":"Units"},"row_2":{"col_1":"10&nbsp;µA","col_2":"1100","col_3":"µA/A"},"row_3":{"col_1":"&gt; 10&nbsp;µA","col_2":"850","col_3":"µA/A"},"row_4":{"col_1":"100&nbsp;µA","col_2":"120","col_3":"µA/A<br>"},"row_5":{"col_1":"&gt; 100&nbsp;µA","col_2":"135","col_3":"µA/A"},"row_6":{"col_1":"&gt; 220&nbsp;µA","col_2":"120","col_3":"µA/A"},"row_7":{"col_1":"1 mA","col_2":"20","col_3":"µA/A"}}
Comparison with reference standard, direct comparison
Approved on 21 December 2023
Institute service identifier : ICE-LMVE/32101
CMC ID : SIM-EM-CR-00000NUN-1
 
DC resistance , DC resistance standards and sources: high values : 1.01E6 Ω to 1.00E8 Ω
Fixed resistor, resistance box
Relative expanded uncertainty : 3.0E1 µΩ/Ω to 1.1E3 µΩ/Ω
{"row_1":{"col_1":"Resistance Value","col_2":"Expanded Uncertainty","col_3":"Units"},"row_2":{"col_1":"1.9 MΩ","col_2":"50","col_3":"µΩ/Ω"},"row_3":{"col_1":"&gt; 1 MΩ","col_2":"260","col_3":"µΩ/Ω"},"row_4":{"col_1":"10 MΩ","col_2":"30","col_3":"µΩ/Ω"},"row_5":{"col_1":"19 MΩ<br>","col_2":"70","col_3":"µΩ/Ω"},"row_6":{"col_1":"&gt; 10 MΩ<br>","col_2":"1100","col_3":"µΩ/Ω"},"row_7":{"col_1":"100 MΩ<br>","col_2":"80","col_3":"µΩ/Ω"}}
Direct comparison
Approved on 21 December 2023
Institute service identifier : ICE-LMVE/21103
CMC ID : SIM-EM-CR-00000NUH-1
 
Impedance (up to the MHz range) , Inductance: self inductance, low values : 10 mH to 100 mH
Fixed inductor
Relative expanded uncertainty : 5.0E1 µH/H
{"row_1":{"col_1":"Inductance Value","col_2":"Parameter","col_3":"Specifications","col_4":"Expanded uncertainty","col_5":"Units<br>"},"row_2":{"col_1":"10 mH","col_2":"Frequency<br>​​​​​​​Current","col_3":"1 kHz<br>​​​​​​​7.7 mA","col_4":"50","col_5":"µH/H"},"row_3":{"col_1":"100 mH","col_2":"Frequency<br>​​​​​​​Current","col_3":"1 kHz&nbsp;<br>1.5 mA","col_4":"50","col_5":"µH/H<br>"}}
Substitution using an LCR meter
Frequency  : 1 kHz
Current :  1.5 mA to 7.7 mA
Approved on 19 January 2024
Institute service identifier : ICE-LMVE/43201
CMC ID : SIM-EM-CR-00000NU7-1
 
Impedance (up to the MHz range) , Impedance (up to the MHz range), capacitance, capacitance and dissipation factor for dielectric capacitors : 10 pF to 1000 pF
Fixed capacitor, capacitance box
Relative expanded uncertainty : 5.0E1 µF/F
{"row_1":{"col_1":"","col_2":"Parameter","col_3":"Specifications","col_4":"Expanded uncertainty","col_5":"Units"},"row_2":{"col_1":"10 pF","col_2":"Frequency Voltage","col_3":"1 kHz 15 V","col_4":"50","col_5":"µF/F"},"row_3":{"col_1":"100 pF","col_2":"Frequency Voltage","col_3":"1 kHz 15 V","col_4":"50","col_5":"µF/F"},"row_4":{"col_1":"1000 pF","col_2":"Frequency Voltage","col_3":"1 kHz 1.5 V","col_4":"50","col_5":"µF/F"}}
Substitution
Frequency : 1 kHz
Voltage : 1.5 to 15 V
Approved on 21 April 2016
Institute service identifier : ICE-LMVE/42201
CMC ID : SIM-EM-CR-000007QY-1
 
DC resistance , DC resistance standards and sources: high values : 10 MΩ to 1.00E5 MΩ
Fixed resistor, resistance box
Relative expanded uncertainty : 1.4E1 µΩ/Ω to 3.0E2 µΩ/Ω
{"row_1":{"col_1":"Nominal Resistance value","col_2":"Units","col_3":"Parameter","col_4":"Specifications","col_5":"Expanded Uncertainty","col_6":"Units"},"row_2":{"col_1":"10<br>","col_2":"MΩ<br>","col_3":"Temperature <br>​​​​​​​Voltage<br>","col_4":"23 °C<br>1 V<br>","col_5":"53","col_6":"µΩ/Ω"},"row_3":{"col_1":"10","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>10 V<br>","col_5":"14","col_6":"µΩ/Ω"},"row_4":{"col_1":"10","col_2":"MΩ<br>","col_3":"Temperature <br>​​​​​​​Voltage","col_4":"23 °C<br>50 V<br>","col_5":"14","col_6":"µΩ/Ω"},"row_5":{"col_1":"10","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>100 V<br>","col_5":"14","col_6":"µΩ/Ω"},"row_6":{"col_1":"100","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>1 V<br>","col_5":"295","col_6":"µΩ/Ω"},"row_7":{"col_1":"100<br>","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>10 V<br>","col_5":"30","col_6":"µΩ/Ω"},"row_8":{"col_1":"100","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>50 V<br>","col_5":"30","col_6":"µΩ/Ω"},"row_9":{"col_1":"100","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>100 V","col_5":"30","col_6":"µΩ/Ω"},"row_10":{"col_1":"100","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>200 V","col_5":"61","col_6":"µΩ/Ω"},"row_11":{"col_1":"100","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>500 V","col_5":"118","col_6":"µΩ/Ω"},"row_12":{"col_1":"100","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>1000 V","col_5":"30","col_6":"µΩ/Ω"},"row_13":{"col_1":"1000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>50 V","col_5":"50","col_6":"µΩ/Ω"},"row_14":{"col_1":"1000","col_2":"MΩ<br>","col_3":"Temperature<br>​​​​​​​Voltage<br>","col_4":"23 °C<br>50 V","col_5":"50","col_6":"µΩ/Ω"},"row_15":{"col_1":"1000<br>","col_2":"MΩ<br>","col_3":"Temperature<br>​​​​​​​Voltage<br>","col_4":"23 °C<br>100 V","col_5":"50","col_6":"µΩ/Ω"},"row_16":{"col_1":"1000","col_2":"MΩ<br>","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>200 V","col_5":"64","col_6":"µΩ/Ω"},"row_17":{"col_1":"1000<br>","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage<br>","col_4":"23 °C<br>500 V","col_5":"119","col_6":"µΩ/Ω"},"row_18":{"col_1":"1000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>1000 V","col_5":"50","col_6":"µΩ/Ω"},"row_19":{"col_1":"10000<br>","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>50 V","col_5":"100","col_6":"µΩ/Ω"},"row_20":{"col_1":"10000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>100 V","col_5":"100","col_6":"µΩ/Ω"},"row_21":{"col_1":"10000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>200 V","col_5":"120","col_6":"µΩ/Ω"},"row_22":{"col_1":"10000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>500 V","col_5":"235","col_6":"µΩ/Ω"},"row_23":{"col_1":"10000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>1000 V","col_5":"100","col_6":"µΩ/Ω"},"row_24":{"col_1":"100000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>10 V","col_5":"150","col_6":"µΩ/Ω"},"row_25":{"col_1":"100000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>50 V","col_5":"150","col_6":"µΩ/Ω"},"row_26":{"col_1":"100000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>100 V","col_5":"150","col_6":"µΩ/Ω<br>"},"row_27":{"col_1":"100000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>200 V","col_5":"150","col_6":"µΩ/Ω"},"row_28":{"col_1":"100000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>500 V","col_5":"249","col_6":"µΩ/Ω"},"row_29":{"col_1":"100000","col_2":"MΩ","col_3":"Temperature<br>​​​​​​​Voltage","col_4":"23 °C<br>1000 V","col_5":"150","col_6":"µΩ/Ω"}}
Automatic resistance bridge
Temperature  : 23 °C
Voltage  : 1 V to 1000 V
Approved on 21 December 2023
Institute service identifier : ICE-LMVE/21303
CMC ID : SIM-EM-CR-00000NUI-1
 
DC resistance , DC resistance standards and sources: low values : 0.1 Ω to 1 Ω
Fixed resistor, resistance box
Relative expanded uncertainty : 2.5E1 µΩ/Ω to 9.0E2 µΩ/Ω
{"row_1":{"col_1":"Resistance Value","col_2":"Expanded Uncertainty","col_3":"Units"},"row_2":{"col_1":"0.1 Ω<br>","col_2":"680","col_3":"µΩ/Ω"},"row_3":{"col_1":"&gt; 0.1 Ω<br>","col_2":"900","col_3":"µΩ/Ω"},"row_4":{"col_1":"1 Ω<br>","col_2":"25","col_3":"µΩ/Ω"}}
Direct comparison
Approved on 21 December 2023
Institute service identifier : ICE-LMVE/21101
CMC ID : SIM-EM-CR-00000NUF-1
 
DC voltage (up to 1100 V) , DC voltage meters: intermediate values : 0.01 V to 1000 V
DC voltmeter, multimeter
Relative expanded uncertainty : 3 µV/V to 9.0E1 µV/V
{"row_1":{"col_1":"Voltage Value","col_2":"Expanded uncertainty","col_3":"Units"},"row_2":{"col_1":"10 mV","col_2":"70","col_3":"µV/V"},"row_3":{"col_1":"&gt; 10 mV&nbsp;","col_2":"90","col_3":"µV/V"},"row_4":{"col_1":"100 mV<br>","col_2":"7","col_3":"µV/V"},"row_5":{"col_1":"&gt; 100 mV<br>","col_2":"20","col_3":"µV/V"},"row_6":{"col_1":"&gt; 220 mV<br>","col_2":"15","col_3":"µV/V"},"row_7":{"col_1":"1 V<br>","col_2":"3","col_3":"µV/V"},"row_8":{"col_1":"&gt; 1 V<br>","col_2":"10","col_3":"µV/V"},"row_9":{"col_1":"&gt; 2.2 V<br>","col_2":"10","col_3":"µV/V<br>"},"row_10":{"col_1":"10 V<br>","col_2":"3","col_3":"µV/V"},"row_11":{"col_1":"&gt; 10 V<br>","col_2":"6","col_3":"µV/V<br>"},"row_12":{"col_1":"&gt; 11 V<br>","col_2":"10","col_3":"µV/V"},"row_13":{"col_1":"&gt; 22 V<br>","col_2":"15","col_3":"µV/V<br>"},"row_14":{"col_1":"100 V","col_2":"5","col_3":"µV/V"},"row_15":{"col_1":"&gt; 100 V","col_2":"10","col_3":"µV/V"},"row_16":{"col_1":"&gt; 220 V<br>","col_2":"10","col_3":"µV/V"},"row_17":{"col_1":"1000 V<br>","col_2":"5","col_3":"µV/V"}}
Direct comparison
Approved on 21 December 2023
Institute service identifier : ICE-LMVE/12201
CMC ID : SIM-EM-CR-00000NUE-1
 

Select Metrology Area

General physics
Acoustics, Ultrasound, Vibration

This metrology area covers the fields of acoustics, ultrasound and vibration.

Electricity and Magnetism

This metrology area covers the fields of DC and AC measurements, impedance, electric and magnetic fields, radiofrequencies and measurements on materials.

Length

This metrology area covers the fields of laser frequencies and dimensional metrology.

Mass and related quantities

This metrology area covers the fields of mass standards, force, pressure, density, hardness, torque, gravity and viscosity.

Chemistry and Biology
Chemistry and Biology

This metrology area covers all fields relevant to chemistry and biology.

Ionizing radiation
Ionizing Radiation

This metrology area covers the fields of dosimetry, radioactivity and neutron measurements.